Seamless, coved and disinfectant-resistant epoxy flooring for hospitals, operating rooms, laboratories and clinics, with an anti-static system in the rooms that need it and an anti-slip system in wet rooms.
Hospital epoxy flooring is a one-piece floor system with no joints or seams that withstands disinfectants and meets the wall in a curved cove base. A 2–3 mm self-leveling epoxy is used in corridors and rooms, anti-static epoxy in operating rooms, textured anti-slip epoxy in wet rooms and epoxy paint in plant rooms. The surface can be walked on after about 24 hours and is fully cured in 7 days; the work is carried out by closing departments in turn.
Hospital epoxy flooring allows the floor in a healthcare building to do two jobs at once: to carry foot and wheeled traffic that goes on around the clock, and to withstand, without deteriorating, the disinfection that is carried out every day, and in some departments several times a day. Here the floor is not merely a building element but a part of the infection control regime.
With jointed floor coverings the problem lies not in the tile itself but in its joint. Cement-based grout is porous; over time it absorbs dirt, blood and cleaning water, its color darkens and a film forms that cannot be removed by wiping. With sheet flooring, on the other hand, the seams and the base of the walls are the weak points; water that seeps beneath a seam that has opened up can remain there unnoticed.
Because an epoxy coating is applied to the floor as a liquid and hardens in place, it contains no seams or joints. When it meets the wall in a curved cove base, the room is cleaned like a one-piece basin with no corners. The surface is non-porous; a spilled liquid does not soak in, it stays on top and is wiped away.
What healthcare facilities expect from a floor can be summarized roughly as follows:
The floor is not stressed in the same way in every department. A system that is right for a corridor may be inadequate in an operating room and slippery in a sterilization unit. Below you will find the areas we work in most often and the details we pay attention to in each of them.
In the general circulation areas of hospitals it is wheels that tire the floor the most. Patient beds, stretchers and service carts travel back and forth along the same line all day, and they turn in front of doors and at elevator entrances. In these areas we apply self-leveling epoxy 2–3 mm thick: because the surface is flat the wheels turn quietly and without jolting, and because there are no joints the stretcher does not catch. Since blood and body fluids are spilled frequently in the emergency department, choosing a light, plain color means that dirt is seen at once. In corridors we recommend a satin finish instead of a gloss one; the reflection of the ceiling lighting on the floor can create the illusion of a wet floor, particularly for elderly patients. Bands in a different color can be laid into the floor to separate departments or to show the way. The points where beds turn, such as the areas in front of elevators and the service entrances, are the places that wear fastest; in these zones particular importance is attached to the abrasion resistance of the topcoat.
Operating rooms are the rooms in which the most is expected of the floor: constant disinfection, sensitive electronic equipment and flawless cleanability. In these rooms anti-static (ESD) epoxy is applied. The system consists of a primer, copper tapes connected to the grounding line of the building, a conductive primer and a conductive self-leveling coat. In this way the static charge that builds up on personnel and equipment flows to ground without a sudden discharge. When the work is finished the surface resistance is measured and the measurement record is handed over. Which resistance range is required is written in the technical specification of the project, and we plan the application according to that value. The wall junctions are always coved, and no difference in level is left at the door threshold. The fixing points of the operating table and of equipment anchored to the floor should be determined before the coating, and no holes should be drilled in the floor afterwards. A matte or satin surface is chosen; the powerful light of the surgical lamp produces reflections on a glossy floor that tire the eyes.
The test of a laboratory floor is chemicals. In biochemistry, microbiology and pathology laboratories, stains, alcohol, acid and alkali solutions and tissue fixatives are used. Self-leveling epoxy withstands short-term spills of most of these substances; for concentrated acids and strong solvents, however, a resin with enhanced chemical resistance has to be selected. This is why we ask for a list of the chemicals in use before preparing a quotation. Although stains do not damage the surface, they can leave a mark if they are left standing; a mid-tone gray or beige shows these marks less. The places where heavy equipment such as centrifuges, deep freezers and analyzers will sit must be flat, so leveling before the coating becomes important here. The areas under the benches and behind the equipment are coated too; edges left half finished become a path for leaks. Because the likelihood of spills is high in the blood collection and specimen reception sections, the base of the walls is coved.
Private clinics are most often located on one floor of an office building or business center; the existing floor is ceramic tile, laminate or an old screed. The expectation here is twofold: hospital-level cleanability in the examination and procedure rooms, and in the reception area a look that suits the identity of the clinic. Plain-colored self-leveling epoxy can be used in the rooms and, if desired, metallic epoxy in the waiting and reception section. Because sound, well-bonded ceramic tile can be coated without being removed, the renovation is carried out without demolition and rubble. In clinics the work is generally planned so that it starts on Friday evening and is ready for Monday morning. In rooms where interventional procedures are performed, such as aesthetics, dermatology and ophthalmology, we recommend a coved base; even in small rooms it noticeably shortens the cleaning time. The transition between the reception area and the examination rooms is resolved with a straight line positioned under the door.
In outpatient clinics, what tires the floor is that thousands of footsteps gather at the same points in the course of a day: the area in front of the registration desk, the queuing area, the blood collection unit and the doors of the examination rooms. Sand and mud from outside are carried in on shoes and abrade the surface like sandpaper. For this reason we recommend leaving an effective entrance matting zone and using an abrasion-resistant matte or satin topcoat on the coating. Here self-leveling epoxy provides both durability and a surface that is easy to wipe. A cove is formed in the blood collection and injection rooms. In waiting areas chair legs create point loads and scratches; fitting protective caps under the legs extends the life of the surface. If colored wayfinding bands for each specialty are laid into the floor, patients find their way without looking for signs. In rooms that get wet, such as toilets and accessible washrooms, a fine sand texture is preferred.
In dental clinics the detail that governs the floor coating is the services. The water, air, suction and electrical lines of every dental unit come up out of the floor; if the surrounds of these outlets are not joined to the coating in a watertight manner, water leaks travel beneath the screed. The coating should not be applied until the unit positions are final, and the service boxes should be fixed in advance. In the treatment rooms we use plain-colored self-leveling epoxy; a light-toned floor without a pattern is useful so that small instruments and burs that have been dropped are easy to find. In the plaster and model room, plaster dust and water are found together, and a finely textured surface is safer here. For the plant enclosure that houses the compressor and the suction motor, epoxy floor paint is sufficient. The sterilization corner, small as it may be, should be coved and suitable for wet wiping. In the panoramic X-ray room the points where the machine will be anchored to the floor are also determined before the coating; anchor holes drilled afterwards break the watertightness.
In veterinary clinics it is not people but animals that put the floor to the test. When urine and feces soak into a porous floor the odor becomes permanent; on a seamless epoxy surface, by contrast, the liquid stays on top and is washed away. Claw scratches show up quickly on a glossy surface, so we choose a matte finish. In addition, dogs cannot get a grip on a smooth floor, and elderly animals and those that have had surgery in particular slip; in the examination, waiting and boarding sections we apply a fine-sand textured epoxy. The texture should be rough enough to hold a paw but fine enough to be washed easily with a brush. In the boarding and washing sections the floor needs to be given a fall toward the drain and the base of the walls needs to be protected with a cove. In the surgery room the cleanability rules of human operating rooms apply in full. Because disinfectants and odor-removal products are used frequently, the surface should be rinsed with plenty of water, and the surrounds of the feet of cages and partitions should be joined to the coating in a watertight manner.
In central sterilization units the floor is divided into three zones, dirty, clean and sterile; separating these zones by floor color prevents staff from mixing up the flow. The washing zone is constantly wet and water containing detergent stays on the floor; here an epoxy with an anti-slip texture is used, and in the packing and sterile storage section a smooth self-leveling system. In front of the autoclaves the situation is different: the hot water and steam that run onto the floor while the machine is being unloaded are demanding for epoxy. Occasional splashes do not cause a problem, but if there is a point where the floor is in continuous contact with water or steam above 60 °C, epoxy is not the right choice there; we state this clearly in the quotation and confirm it during the site survey. Connecting the discharge lines of the machines directly to the drain eliminates this problem most of the time. The surrounds of the drains under the washer-disinfectors and sinks are joined to the coating, and the base of the walls is coved.
Using a single type of coating throughout a hospital either costs more than necessary or falls short in some departments. The right approach is to classify each area according to its own conditions:
You can find more detailed information for hospital kitchens on our food plant floors page and for indoor parking on our parking garage epoxy flooring page. The student laboratories of medical and dental schools are covered on the educational institutions page.
In healthcare buildings the quality of a coating is determined not by the flat surface but by the edges. The right-angled corner where the floor meets the wall is the place that neither the mop nor the machine can reach. A cove means rounding this corner with a quartz-filled epoxy paste and carrying the coating up the wall, generally by 5–10 cm. In this way the washing water does not seep into the base of the wall and dirt does not collect in the corner.
At door thresholds the coating is finished at the same level as the floor of the adjoining room; no lip is left for the wheels of stretchers and beds to catch on. Where different floor coverings meet, a slim transition profile is used. The surrounds of drains and cleanout covers are joined to the coating. The expansion joints of the building, however, are not closed off beneath the coating; they are dealt with separately using a flexible filler.
Closing a hospital for the sake of the floor is not possible; the work is always phased. On the ward floors the rooms are vacated in turn. Corridors can be divided in two lengthwise, with one half coated first and the other half after the first has become walkable; in this way passage is never interrupted. The line where the two halves meet is planned as a straight run and is most often concealed by a band of color.
In departments that work during the day, such as outpatient clinics and imaging, the weekend is used, and in operating rooms the planned maintenance period. In units that never stop, such as the emergency department, a temporary patient route has to be created; we draw this up together with the hospital management.
The systems we use contain no solvents and are low in odor; even so, during application the ventilation of the department is kept separate from the patient areas. The times depend on the ambient temperature: at around 20 °C the surface opens to foot traffic in about 24 hours, and for wheeled loads such as patient beds and heavy equipment it is right to wait a few days. Full cure takes 7 days; because chemical resistance develops at the end of this period, we ask for damp wiping instead of heavy use of disinfectants during the first week.
The daily care of an epoxy floor is simple: damp wiping with a microfiber mop and a neutral floor detergent are sufficient for most departments. In wide corridors a scrubber-dryer with a soft pad can be used. Textured surfaces should be washed not with a mop but with a machine fitted with brushes or with a stiff brush; otherwise the dirt stays inside the texture.
The coating withstands the recommended in-use concentrations of common surface disinfectants based on chlorine, alcohol and quaternary ammonium. The point to watch is concentration and contact time: if chlorine-based products at high concentration are left on the surface for a long time, they can cause dulling and fading over time. Rinsing the surface at the end of the time stated on the product label prevents this effect.
Antiseptics containing iodine, some laboratory stains and strong colorants such as hair dye can leave a mark if they are left standing; a spill should be wiped up immediately. Abrasive pads and wire brushes scratch the topcoat and should not be used. If the surface goes dull over the years on lines that see heavy traffic, the floor is not stripped out; it is renewed by sanding it lightly and applying a new topcoat.
For a daily, weekly and yearly maintenance schedule and cleaning tips for each type of stain, see our guide Epoxy Floor Maintenance and Cleaning.
On hospital floors the cost is not determined by the material alone. The main items that affect a quotation are these:
For this reason our itemized quote, prepared from the floor plan, photos and the information you send us, lists these items separately; once the quote is approved, we see and measure the departments during the on-site survey and confirm which items are needed.
We explain what to look for when comparing quotes in our article 7 Factors That Determine the Cost of Epoxy Flooring per m².
If you would like to find out the price and the duration for your hospital, clinic or laboratory, it is enough to fill in the quotation form. Adding the information below allows us to determine the right system and a realistic schedule more quickly:
To examine the systems in detail you can take a look at the services page, and for your questions you can reach us through the contact page.
| Recommended system | 2–3 mm self-leveling epoxy in corridors and rooms |
|---|---|
| Conductive areas | Anti-static (ESD) epoxy, handed over with resistance measurements |
| Wet rooms | 3–5 mm textured (anti-slip) epoxy |
| Cove base | Curved epoxy cove, 5–10 cm high |
| Surface preparation | Diamond grinding with dust extraction |
| Open to foot traffic | Approx. 24 hours |
| Full cure | 7 days (20 °C) |
Yes, a fully cured epoxy floor is not affected by the recommended in-use concentrations of common surface disinfectants based on chlorine, alcohol and quaternary ammonium. What causes problems is using the product undiluted or leaving it on the surface for hours; in that case the gloss can decrease. Because chemical resistance is not yet complete during the first 7 days after application, we recommend damp wiping only. In departments where special chemicals are used, such as laboratories, the resin is selected according to the product list.
Because sensitive electronic equipment operates in an operating room, and a sudden discharge of the static charge generated by the movement of personnel can affect that equipment. Anti-static epoxy transfers the charge to the grounding line of the building through copper tapes and conductive layers. In appearance it cannot be told apart from standard epoxy; the difference is revealed by the resistance measurement taken at handover. The required resistance range is determined by the specification of the project. Polish must not be used on these floors, otherwise conductivity falls.
Yes, a corridor can be coated without interrupting passage by dividing it lengthwise into two lanes. One half is prepared and coated first, it is opened to foot traffic after about 24 hours and work moves on to the other half. Patient rooms and outpatient clinics are vacated in turn; for units that never stop, such as the emergency department, a temporary route is planned. Because the work area is separated by partitions and sheeting and the grinding machines have dust extraction, the neighboring departments are not affected. As the number of phases rises, the total duration becomes longer; we draw up the schedule together with the hospital management.
If the ceramic tile is sound it can be coated over, whereas vinyl and similar sheet flooring has to be removed. With ceramic, the tiles are checked one by one, those that sound hollow are taken out, the surface is roughened with diamond tooling and the joints are filled and leveled. Sheet flooring is removed completely, because it is flexible and the adhesive underneath prevents the epoxy from bonding; the adhesive residue is ground away down to the concrete. Which route will be followed becomes clear during the site survey.
Smooth, glossy epoxy is safe when dry, but when water stands on it, it can become slippery like any smooth floor. This is why, in sections that get wet such as patient bathrooms, kitchens, laundries and washing rooms, quartz sand is broadcast onto the surface to give it a textured finish. In corridors and rooms a matte or satin topcoat is preferred; it reduces the reflection of the lighting and prevents the floor from looking wet. The fineness of the texture is chosen with the cleaning method in mind; a very coarse texture cannot be wiped with a mop.
In an environment at around 20 °C, the department can be used on foot after about 24 hours. Waiting a few days before bringing in wheeled loads such as patient beds, stretchers and heavy equipment prevents marks from being left on the surface. The coating reaches its full hardness and chemical resistance in 7 days. In a cool environment these times become longer, which is why the area has to be heated in the winter months. Including preparation and the waiting time between coats, the work on a single department generally takes a few days; the exact duration is stated in the quotation according to the system and the size of the area.
An epoxy floor needs little maintenance, but it should not be neglected. Everything you need to know, from daily cleaning and stain removal to the…
We explain in plain language what epoxy flooring is, which types are available and why it is chosen for different kinds of spaces.
Every stage of an epoxy flooring installation from survey to handover: surface preparation, repairs, primer, coating layer and curing.
When can you walk on an epoxy floor, and when can it take loads? Curing times by temperature and the conditions that affect the process.
Why do epoxy flooring prices vary so much from one project to the next? We explain the items that make up the price so that you can compare quotes…
Our priority is
Tell us about your project, and together we will pin down the right epoxy system for your floor, the application time and our quote.
Get a Quote5-year workmanship and 10-year product warranty. We respond to all requests within 24 hours. We work in all 81 provinces.